Identify Start Command 

RapidHA Primary Header0x11 (General Cluster Frames)
RapidHA Secondary Header0x10

...

  • F1 11 10 DE 01 16 16 01 [RHAIdentifyStart]

Identify Stop Command 

RapidHA Primary Header0x11 (General Cluster Frames)
RapidHA Secondary Header0x11

...

  • F1 11 11 E3 01 16 1C 01 [RHAIdentifyStop]

On/Off Status Update 

RapidHA Primary Header0x12 (HA Cluster Frames)
RapidHA Secondary Header0x00

...

  • (Indicating OFF) F1 12 00 DF 03 16 00 00 0A 01 [RHAOnOffStateUpdate]

Move to Level with On/Off Status

RapidHA Primary Header0x12 (HA Cluster Frames)
RapidHA Secondary Header0x25 (note that this is different from the secondary header for the Move to Level command, which is 0x20)

...

  • (Indicating Level 100, Transition Time 0, On/Off Status ON) F1 12 25 BB 05 16 64 00 00 01 72 01 [RHAMoveToLevel]


Module Triggered Restore to Factory Defaults Command

...

RapidHA Primary Header0x55 (Utility Frames)
RapidHA Secondary Header0x10


Expected Host Action

The If the product makes use of the pin for the Factory Reset Button, then this command is optional. The Restore Defaults frame is sent from the Host to the Module and serves to restore the Module to its factory default settings. The command has no payload.

...