Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

The commands in this section facilitate over the air (OTA) server of the application operating on the Module. These commands have been implemented per the ZigBee HA 1.2 guidelines.

Secondary Headers


In This Space






( PH:0xB0, SH:0x00 ) - OTA Image Notification Command

The OTA Image Notification Command frame is sent from the Host to the Module. The Module will send an Image Notify ZCL command either broadcast or unicast depending on the received serial frame.

Payload for OTA Image Notification Command

Byte Index

Field Name

Notes

0,1

Node ID

Target Device Node ID
 0xFFFF means the EUI64 is used.

2..9

EUI64 Address

Target Device EUI64. All 0xFF indicates broadcast

10

Endpoint

0xFF indicates a request on all endpoints.

11

Payload Type

0x00 = Query jitter
0x01 = Query jitter & manufacturer code
0x02 = Query jitter, manufacturer code & image type
0x03 = Query jitter, manufacturer code, image type &
             new file version
0x04-0xFF Reserved

12

Query Jitter


(13,14)

Manufacturer Code

Optional field, it is needed for payload type 0x01-0x03

(15,16)

Image Type

Unused - for backwards compatibility. Set to 0x0000

(17..20)

File Version

Will contain the value initially set in the Query Next Image Response / OTA Query Next Image Response frames by the Host.


Allowed ContextSent By Host/Module
All Contexts






( PH:0xB0, SH:0x01 ) - OTA Query Next Image Request Command

The OTA Query Next Image Request frame is sent from the Module to the Host. The Module expects to receive an OTA Query Next Image Response frame in return.

Payload for OTA Query Next Image Request Command

Byte Index

Field Name

Notes

0,1

Node ID

Request OTA Device Node ID

2..9

EUI64 Address

Request OTA Device EUI64

10

Endpoint

Request OTA Device Endpoint

11

Field Control

8-bit Bitmap
Bit 0 : Hardware Version
            0=unavailable
            1=present
Bit 1-7: Reserved

12,13

Manufacturer Code


14,15

Image Type

Unused - for backwards compatibility. Set to 0x0000

16..19

File Version

Optional. Number used here will be echoed back in all subsequent frames for the transaction. For example, this field can be used by the Host to differentiate multiple concurrent updates, or for any other purpose the Host requires.

(20,21)

Hardware Version

Optional. Bit 0 of "Field Control" must equal "1" to use this optional field.


Allowed ContextSent By Host/Module
All Contexts

( PH:0xB0, SH:0x02 ) - OTA Query Next Image Response Command

The OTA Query Next Image Response frame is sent from the Host to the Module. The Module relays the frame to the OTA target device. If the target EUI64 is the module’s own EUI64, the module will process it locally.

Payload for OTA Query Next Image Response Command

Byte Index

Field Name

Notes

0,1

Node ID

Target Device Node ID. 0xFFFF indicates that the EUI64 is used

2..9

EUI64 Address

Target Device EUI64

10

Endpoint

Target Device Endpoint

11

Status

0x00 – Success
0x80 – Malformed Command
0x81 – Unsupported Cluster Command
0x95 – Abort
0x96 – Invalid Image
0x97 – Wait for Data
0x98 – No Image Available
0x99 – Require Mode Image
0x7E – Not Authorized

12,13

Manufacturer Code


14,15

Image Type

Unused - for backwards compatibility. Set to 0x0000

16..19

File Version

Will contain the value initially set in the Query Next Image Response / OTA Query Next Image Response frames by the Host.

20..23

Image Size



Allowed ContextSent By Host/Module
All Contexts






( PH:0xB0, SH:0x03 ) - OTA Image Block Request Command

The OTA Image Block Request frame is sent from the Module to the Host. The Module expects to receive an OTA Image Block Response frame in response.

Payload for OTA Image Block Request Command

Byte Index

Field Name

Notes

0,1

Node ID

Request OTA Device Node ID

2..9

EUI64 Address

Request OTA Device EUI64

10

Endpoint

Request OTA Device Endpoint

11

Field Control

8-bit Bitmap
Bit 0 : Request node’s IEEE address
           0=unavailable
           1=present
Bits 1-7 : Reserved

12,13

Manufacturer Code


14,15

Image Type

Unused - for backwards compatibility. Set to 0x0000

16..19

File Version

Will contain the value initially set in the Query Next Image Response / OTA Query Next Image Response frames by the Host.

20..23

File Offset


24

Maximum Data Size

N < 50

Expected Host Action

The Host must process and respond to Image Block Request messages until the Module sends a Upgrade End Request

The  Host must set status to MALFORMED_COMMAND (0x80) and return a 0 length data block if the Image Offset is outside the range of the file length.


Allowed ContextSent By Host/Module
All Contexts

( PH:0xB0, SH:0x05 ) - OTA Image Block Response Command

The OTA Image Block Response frame is sent from the Host to the Module. The Module relays the frame to the OTA target device. If the target EUI64 is the module’s own EUI64, the module will process it locally.

There are three possible return values for the OTA Image Block Response: Success, Wait for Data, and Abort. The payload differs for each one.

Payload for OTA Image Block Response Command on Success

Byte Index

Field Name

Notes

0,1

Node ID

Target Device Node ID. 0xFFFF indicates that the EUI64 is used.

2..9

EUI64 Address

Target Device EUI64.

10

Endpoint

0xFF indicates a request on all endpoints.

11

Status

0x00 = Success

12,13

Manufacturer Code


14,15

Image Type

Unused - for backwards compatibility. Set to 0x0000

16..19

File Version

Will contain the value initially set in the Query Next Image Response / OTA Query Next Image Response frames by the Host.

20..23

File Offset


24

Data Size

N < 50

25..(24+N)

Data


Payload for OTA Image Block Response Command on Wait for Data

Byte Index

Field Name

Notes

0,1

Node ID

Target Device Node ID. 0xFFFF indicates that the EUI64 is used.

2..9

EUI64 Address

Target Device EUI64.

10

Endpoint

Target Device Endpoint

11

Status

0x97 = Wait for Data

12..15

Current UTC Time

The current UTC time

16..19

Request Time

The UTC time the client should retry the request

20

Checksum LSB

The least significant byte of the 16-bit CS.

21

Checksum MSB

The most significant byte of the 16-bit CS.

Payload for OTA Image Block Response Command on Abort

Byte Index

Field Name

Notes

0,1

Node ID

Target Device Node ID. 0xFFFF indicates that the EUI64 is used

2..9

EUI64 Address

Target Device EUI64

10

Endpoint

Target Device Endpoint

11

Status

0x95 = Abort


Allowed ContextSent By Host/Module
All Contexts






( PH:0xB0, SH:0x06 ) - OTA Upgrade End Request Command

The Upgrade End Request frame is sent from the Module to the Host. The Module expects to receive an Upgrade End Response frame in response.

Payload for OTA Upgrade End Request Command

Byte Index

Field Name

Notes

0,1

Node ID

Request OTA Device Node ID

2..9

EUI64 Address

Request OTA Device EUI64

10

Endpoint

Request OTA Device Endpoint

11

Status

0x00 – Success
0x95 – Abort
0x96 – Invalid Image
0x99 – Require Mode Image

12,13

Manufacturer Code


14,15

Image Type

Unused - for backwards compatibility. Set to 0x0000

16..19

File Version

Will contain the value initially set in the Query Next Image Response / OTA Query Next Image Response frames by the Host.


Allowed ContextSent By Host/Module
All Contexts

( PH:0xB0, SH:0x07 ) - OTA Upgrade End Response Command

The OTA Upgrade End Response frame is sent from the Host to the Module in response to an OTA Upgrade End Request with success status. The Module relays the frame to the OTA target device. If the target EUI64 is the module’s own EUI64, the module will process it locally,

Payload for OTA Upgrade End Response Command

Byte Index

Field Name

Notes

0,1

Node ID

Target Device Node ID. 0xFFFF indicates that the EUI64 is used.

2..9

EUI64 Address

Target Device EUI64. All 0xFF indicates broadcast

10

Endpoint

0xFF indicates a request on all endpoints.

11,12

Manufacturer Code


13,14

Image Type

Unused - for backwards compatibility. Set to 0x0000

15..18

File Version

Will contain the value initially set in the Query Next Image Response / OTA Query Next Image Response frames by the Host.

19..22

Current Time


23..26

Upgrade Time



Allowed ContextSent By Host/Module
All Contexts
  • No labels