This page describes the commands supported by the RapidHA serial protocol. The payload byte values are detailed in the command descriptions. Some commands have no payloads.

...

Note
titleNew in RapidHA v1.7

New sleep control frames under the Utility command group (PH: 0x55) provide the user with a wake-up handshaking scheme, as well as total and accurate control of application sleep cycles.


Table of Contents
maxLevel2
minLevel2

...

Frame NameSecondary Header ByteAllowed ContextSent By Host/Module
Reset0x00All ContextsHost
Module Info Request0x02All ContextsHost
Module Info Response0x03N/AModule
Bootloader Version Request0x04All ContextsHost
Bootloader Version Response0x05N/AModule
Application Version Count Request0x06All ContextsHost
Application Version Count Response0x07N/AModule
Application Version Request0x08All ContextsHost
Application Version Response0x09N/AModule
Restore Defaults0x10All ContextsHost
Host Startup Ready0x20All ContextsHost
Startup Sync Request0x21All ContextsModule
Startup Sync Complete0x22Startup Config OnlyHost
Antenna Configuration Request0x23All ContextsHost
Antenna Configuration Response0x24N/AModule
Antenna Configuration Write0x25All ContextsHost
LED Configuration Request0x26All ContextsHost
LED Configuration Response0x27N/AModule
LED Configuration Write0x28All ContextsHost
Serial ACK Config Write0x30All ContextsHost
Serial ACK Config Request0x31All ContextsHost
Serial ACK Config Response0x32N/AModule
Manufacturer ID Request0x40All ContextsHost
Manufacturer ID Response0x41N/AModule
Manufacturer ID Write0x42Startup Config OnlyHost
Sleepy Parameters Request CMD0x50All ContextsHost
Sleepy Parameters Response CMD0x51N/AModule
Sleepy Parameters Write CMD0x52All ContextsHost
Sleepy Hibernate Duration Request CMD0x53All ContextsHost
Sleepy Hibernate Duration Response CMD0x54N/AModule
Sleepy Hibernate Duration Write CMD0x55All ContextsHost
Sleep Control Stay Awake Duration Write0x58All ContextsHost
Sleep Control Stay Awake Duration Read0x59All ContextsHost
Sleep Control Stay Awake Duration Response0x5AAll ContextsModule
Status Response0x80N/AHost or Module
Sleep Control Wakeup0xA0All ContextsHost
Error0xE0All ContextsModule

Anchor
Reset
Reset
Reset Command - ( PH:0x55 SH:0x00 )

The Reset command is sent from the Host to the Module, and prompts the Module to reboot. The command has no payload.

...

 The Application Version Count Response is sent from the Module to the Host. The response payload length is 1 octet.

Payload for Application Version Count Response Command


Byte Index

Field Name

Notes

0

Version String Count

A count of the total number of Application Version Strings available from the running application.

Expected Host Action

None. 

Anchor
Application Version Request
Application Version Request
Application Version Request - ( PH:0x55, SH:0x08 )

The Application Version Request is sent from the Host to the Module to query a given Application Version String describing either the Application Bootloader Version, the core RapidHA Version or the Virtual Host Application Version. The request payload length is 1 octet. 

Payload for Application Version Request Command

Byte Index

Field Name

Notes

0

Version Index

0x00 - Retrieve Bootloader Version
0x01 - Retrieve RapidHA Version
0x02 - 0xFF - Retrieve Virtual Host Version 

Effect on Receipt

The Module will respond with an Application Version Response.

Anchor
Application Version Response
Application Version Response
Application Version Response - ( PH:0x55, SH:0x09 )

The Application Version Response is sent from the Module to the Host. The response payload length is variable.

Payload of Application Version Response Command

Byte Index

Field Name

Notes

0

Version String Index

The array index (0 based) that this command relates to. 

1Version TypeThe type of version string returned. See Version Types.
2..(n + 3)VersionThe version being returned. The length n is specified in the first octet of the field. A total of n bytes will follow this length byte containing data which shall be interpreted based on the Version Type.

Expected Host Action

None.

Anchor
Application Version Types
Application Version Types
Version Types
 

Type ID

Type Name

Length (Octets)

0x00

LSB Binary Type

4

0x01MSB Binary Type4
0x02String TypeVariable
0x03LSB Binary Type2
0x04MSB Binary Type2
0x05 - 0xFEReservedN/A
0xFFInvalidN/A 


LSB Binary Type
 

A type value of LSB Binary Type indicates that the version string is being provided as a series of binary encoded bytes that represent the version string in a dotted version format with the least significant byte provided first. For example, a binary value of 0x01,0x02,0x03,0x04 provided using this encoding would be translated to 4.3.2.1 (or possibly 4.3.2rc1) when displayed to the user. This is the default encoding for version numbers.

MSB Binary Type

A type value of MSB Binary Type indicates that the version string is being provided as a series of binary encoded bytes that represent the version string in a dotted version format with the most significant byte provided first. For example, a binary value of 0x05,0x06,0x07, 0x08 provided using this encoding would be translated to 5.6.7.8 (or possibly 5.6.7rc8) when displayed to the user.

String Type

A type value of String Type indicates that the version string is being provided as an ASCII encoded string of length n. The value will not be null terminated as the length is provided. For example, a binary value of 0x31,0x2e,0x32,0x2e,0x30,0x72,0x63,0x31 provided using this encoding would be translated to 1.2.0rc1.

Invalid

A type value of Invalid indicates that the requested element is invalid. Typically this indicates that a request was made for an index which lies outside of the valid range of version string indices.

Anchor
Restore Defaults
Restore Defaults
Restore Defaults Command - ( PH:0x55, SH:0x10 )

The Restore Defaults frame is sent from the Host to the Module and serves to restore the Module to its factory default settings. The command has no payload.

Effect on Receipt

The Module restores all non-volatile elements to their factory default settings, leaves the network if it is joined to one or dissolves the network if it has formed one, and then reboots.

Anchor
Host Startup Ready
Host Startup Ready
Host Startup Ready Command - ( PH:0x55, SH:0x20 )

The Host shall send the Host Startup Ready command to the Module after it starts up and is ready for communication. The command has no payload.

Effect on Receipt

On receiving the command, the Module will respond with the Startup Sync Request command. If the Module is in the Already Running state (see payload for Startup Sync Request ), it signifies that this command was received due to an unexpected reset of the Host. In this case, the Module will have retained all its application cache and attribute values, but will suspend network operations and return to the Startup Synchronization phase.

Anchor
Startup Sync Request
Startup Sync Request
Startup Sync Request Command - ( PH:0x55, SH:0x21 )

The Startup Sync Request command is sent by the Module on startup or as a response to the Host Startup Ready command. Upon issuing this command, the Module suspends execution of the full application until the Host has completed all desired configuration and updates against it. 

The Module resends this command every five seconds until the Host sends the Startup Sync Complete command in response, signaling the completion of the configuration and update process.

Payload for Startup Sync Request Command

Byte Index

Field Name

Notes

0

Running State

0x00 = Starting Up
0x01 = Already Running

1

Configuration State

0x00 = Factory Default
0x01 = Needs Endpoint Configuration
0x02 = Fully Configured

The Running State indicates whether the Module has just powered up or is already running. If the Running State indicates the latter, it signifies that the Host experienced a unilateral reset.

The Configuration State indicates the application configuration state of the Module. The Factory Default state indicates that the Module is operating for the first time post-production, or subsequent to the reception of the Restore to Default command from the Host. The Needs Endpoint Configuration state indicates that the Module has restored all default configurations (Manufacturer ID, etc.), but still requires the Host to configure application endpoints, clusters and attributes. This state will occur after a soft or hard reset of the Module, regardless of the amount of non-volatile memory available.

Expected Host Action

The Host may receive the Startup Sync Request either during a synchronized power up or after a unilateral reset of the Module. The Host shall process both scenarios in the same manner.

If the Running State of the Module is Already Running the Host is not required to configure endpoints, clusters and attributes and perform updates on the values of the latter. Instead, the Host should query attribute values and cached event data from the Module in order to synchronize its internal state with that of the application.

If the Configuration State of the Module is Factory Default, the Host shall perform a full configuration of the application, specifying the IEEE functional device type, security configuration, endpoints, etc. If the Configuration State is Needs Endpoint Configuration, the Host shall configure the application endpoints, clusters and attributes accordingly. If Configuration State is Fully Configured, no further configuration action is required of the Host.

Anchor
Startup Sync Complete
Startup Sync Complete
Startup Sync Complete Command - ( PH:0x55, SH:0x22 )

The Host shall send the Startup Sync Complete command to the Module in response to a Startup Sync Request and upon completion of all startup configurations and updates to the latter. The command has no payload.

Effect on Receipt

The Module acknowledges reception of the command with a Status Response indicating Success, after which it runs the full application. If the Module was previously joined to a network it will rejoin that network. Additionally, application configurations are backed up to non-volatile memory for restoration on the next startup.

Please note that Host configurations for endpoints, clusters and attributes are not preserved in non-volatile memory; thus they must be reconfigured after any soft or hard reset of the Module.

Status Response to Startup Sync Complete Command

Status Response

Enum

Description

Success

0x00

Module received the command and will start the full application.


...

Byte Index

Field Name

Notes

0..3

Channel Mask

4-byte channel mask. Each bit represents channels 0 – 31.  The least significant bit, bit 0, corresponds to channel 0, bit 1 to channel 1, etc.

Example: Channel 11 = 0x00000800 or interpreted as a 32-bit bitmap - 0000 0000 0000 0000 0000 1000 0000 0000 - bit 11 would be flipped

Channel 13 = 0x00002000 or interpreted as a 32-bit bitmap - 0000 0000 0000 0000 0010 0000 0000 0000 - bit 13 would be flipped

ZigBee HA and SE only operate on channels 11-26 (inclusive). If multiple channels are selected, the Module will form a network on the channel with the least interference.

Please note: In order to comply with FCC regulations, MMB Networks devices operate at a reduced power level on channel 26 is restricted. Networks formed on this channel are in violation of FCC rules and regulations.   26 to stay within FCC regulations. It's not recommended to form a network on this channel as it will have a reduced range.

4

Auto Options

Bit 0 = 1 – Auto PAN ID
Bit 1 = 1 – Auto Extended PAN ID

5,6

Short PAN ID

The Short PAN ID of the new network.

7..14

Extended PAN ID

The Extended PAN ID of the new network.

...

The Attribute Report Passthrough Control message is sent from the Host to the Module. The payload length is 1 octet.

Payload for Attribute Report Passthrough Control

Byte Index

Field Name

Notes

0

Attribute Passthrough Control

0x00 = Disabled
0x01 = Enabled 

...

  • (Indicating Level 100, Transition Time 0, On/Off Status ON) F1 12 25 BB 05 16 64 00 00 01 72 01 [RHAMoveToLevel]


Anchor
Lock Door
Lock Door
Lock Door Command  - ( PH:0x012, SH:0x60 )

...