This page shows the pinout that has been pre-configured in the RapidConnect Lighting & Sensor firmware. For more details regarding peripheral compatibility or use 

Interface Summary

Digital In: PIR Occupancy Sensor, Ultrasonic Occupancy Sensor, Factory Reset Button

Analog In: Illuminance Measurement Sensor

Digital Out: Network Status LED (PTI_DATA), Relay

Analog Out: PWM

Serial: UART TX, UART RX

Others: nReset, VCC, GND, JTDO, JTCK, JTD, JTMS, JRST, PTI_EN

Pinout Using Z357PA40-SMT Module

Notes:

  • All pins have maximum sourcing and sinking current of 4mA.
  • EM357 runs off a 3.3V 
  • (*) indicates ADC capable pin
  • (#) indicates PWM capable pin
Module PadFunctionRelation to zigbee FeaturesEM357 GPIO Hardware Integration Comments
1

PIR Digital In

When this input is triggered, the Occupancy Sensor Endpoint will inform the network that Occupancy is "true"PC6 (13)
  • INPUT - Digital (Active Low)
  • Internal Pull-up
  • Requires Hardware Debounce
  • USAGE INSTRUCTIONS
2

Relay Out

When On/Off commands are sent to the Dimmable Light Endpoint, thisPC7 (14)OUTPUT - Digital (Active High)
3

Reserved


PA7 (18)#Reserved for Future PWM
4VCC (3.3 VDC)


5nCTS / SPI Slave CLK
PB3 (19)#Reserved for Future PWM
6

nRTS / SPI Select (Host Controlled Handshake Line)


PB4 (20)#Reserved for Future PWM
7

nReset, active low


(12)
8

Network LED (PTI_EN)


PA4 (26)*OUTPUT - Digital (Active High)
9

Reserved (PTI_DATA)


PA5 (27)*
10

JTDO


PC2 (33)
11

JTCK


(32)
12

JTD


PC3 (34)
13JTMS
PC4 (35)
14JRST
PC0 (40)
15

RXD, SPI Slave In


PB2 (31)UART Serial RX
16

PWM Out


PA6 (29)#
  • OUTPUT - Digital (Active High)
  • 1k Hz Frequency
17

TXD, SPI Slave Out


PB1 (30)UART Serial TX
18GND


19

Ultrasonic Digital In


PC1 (38)*
  • INPUT - Digital (Active Low)
  • Internal Pull-up
  • Requires Hardware Debounce
  • USAGE INSTRUCTIONS
20

Illuminance Analog In


PB7 (41)*INPUT - Analog (0 - 1.2V)
21

Network Button


PB6 (42)*
  • INPUT - Digital (Active Low)
  • Internal Pull-up
  • Requires Hardware Debounce
  • Hold low for >5 seconds to initiate Factory Reset