Firmware

 Version 1.5.7
1.5.7

Release Notes:

New Features
    • None

Bug Fixes
    • [RHA-837] - RF Output Power and Channel Agility

      • All previous outstanding issues with RF Output Power have been resolved
      • When moving channels, the application will now apply the appropriate RF Output Power when scanning on the new channel
Known Issues
    • None

Files:

OTA Upgrade Firmware Imagerapidha-1.5.7-prod.ota
Serial Upgrade Firmware Imagerapidha-1.5.7-prod.mbl
 Version 1.5.6
1.5.6

Release Notes:

New Features
    • None

Bug Fixes
    • [RHA-831] - OTA Adaptation for Daintree ControlScope Networks
      • Implemented functionality to ensure correct operation of OTA upgrades on both standard HA 1.2 and Daintree ControlScope networks
    • [RHA-847] - Attribute Reporting Behaving Incorrectly when Manufacturing Bit Enabled

      • Per summary, corrected an issue where incoming Attribute Reports with the Manufacturing Bit enabled in Frame Control were rejected by the application with a default response
Known Issues
    • [RHA-837] - RF Output Power and Channel Agility

      • Though the more critical issue of the application transmitting at maximum output during the Scan/Join cycle has been resolved (see Bug Fixes) there remains a secondary issue:

      • The application will always apply the RF Output Power of the first channel the application joined to

      • This implies that when moving to a new network (i.e. in pursuit of the coordinator) the application will apply the same RF Output Power when transmitting on the new channel

      • This issue is minor, but we would caution that users should avoid operating the application on Channel 26 where possible

Files:

This release has been retired in favour of RapidHA v1.5.7 and is no longer supported

 Version 1.5.3
1.5.3

Release Notes:

New Features
    • [RHA-796] - Application Version Request

      • Application now includes facilities for querying the Virtual Host application version

      • New frames under Utility command group (PH 0x55):

      • Application Version Count Request (0x06) (H > M)

      • Application Version Count Response (0x07) (M > H)

      • Application Version Request (0x08) (H > M)

      • Application Version Response (0x09) (M > H)

    • [RHA-805] - Incoming Attribute Report Passthrough

      • Application now includes facilities for enabling passthrough of incoming Attribute Reports to the Host

      • New frame under ZigBee Configuration Support command group (PH 0x03):

        • Attribute Report Passthrough Control (SH 0x26) (H > M)

           

Bug Fixes
    • [RHA-837] - RF Output Power

      • It was determined that regardless of the RF Output Power configuration applied at manufacturing time, the application would transmit at maximum output during the Scan/Join cycle

      • The application would then apply the expected RF Output Power once joined to the network

      • This issue has since been corrected, with the RF Output Power being applied during the Scan/Join cycle as expected

Known Issues
    • [RHA-837] - RF Output Power and Channel Agility

      • Though the more critical issue of the application transmitting at maximum output during the Scan/Join cycle has been resolved (see Bug Fixes) there remains a secondary issue:

      • The application will always apply the RF Output Power of the first channel the application joined to

      • This implies that when moving to a new network (i.e. in pursuit of the coordinator) the application will apply the same RF Output Power when transmitting on the new channel

      • This issue is minor, but we would caution that users should avoid operating the application on Channel 26 where possible

Files:

This release has been retired in favour of RapidHA v1.5.7 and is no longer supported.


 

 

  • No labels