RapidConnect Serial Frame 0x01 0x00 (Join Network Command) is superseded by 0x01 0x30 (Network Steering Command), in order to comply with ZB3.0 requirements. Network Steering prompts the device to automatically scan and attempt to join a network, first by Install Code, then using the well-known link key to attempt to join a Centralized Network, and finally attempting to join a Distributed network.
Zigbee Router no longer perform RejoinRequest upon power cycle. Also, it will not perform TCLK update.
Finding and Binding Support.
Clusters must be categorized by Type1/2 and application/utility
Update TC Install Code commissioning Process
Scene Server Cluster revision update
On/Off Server Cluster revision update
Level Control Server Cluster revision update
Network Commissioning: ZR shall not trigger a TC rejoin procedure after a power cycle
Bug Fixes
ZCL Send Multicast/Broadcast: Cluster not found when sending ZCL general command without client cluster
LC-TC-02S: Occasionally failing on step 11c
Sleep Control Stay Awake Duration Write frame not retaining values
Network Commissioning: Enterprise 2.7 can only join up to 3 devices by install code
Condor without flash firmware upgrade in fast mode is not fast
mmbSendIeeeAddrRequest using incorrect ZDO sequence number
Better recovery mechanism for incompatible bootloader
Coordinator opens permit join incorrectly
Race condition in network engine on network join
Condor SED fast polling at 1 second instead of 0.5 second
Dev key RapidConnect v3.4.7, v3.4.8 missing on Potemkin
Client Clusters support attribute 0xFFFD
DUT Router: failed at step 12 for FB-PRE-TC-02 (ZR)
LC-TC-02S: failing on step 9c and 10c
Default reporting implemented on Thermostat and Illum Measurement Server Cluster
Network Commissioning: Permit join not reset when devices leaves network
OTA Upgrade and Serial Upgrade on Legacy Devices Causes Module to Reset before Upgrade Completely Downloads
Deprecated
Commissioning Cluster Support has now been deprecated.
Known Issues
EmberZNet Stack Bug: Cannot join more than 5 ZB3.0 RFD to a coordinator
This issue is under investigation by SiLabs
Special Notes
Warning!
As of RapidConnect 3.4.0, firmware images have been encrypted with an updated bootloader security key. Devices operating releases prior to 3.4.0 (e.g. 3.3.x and below) may not be serially or OTA upgraded in the field to this release.
If you would like to upgrade hardware running pre-3.4.x firmware, please consult with MMB support.
Serial Protocol Specification
You can find our RapidConnect Serial Protocol v3.5.0here.
Download Links
MMB Condor Modules & USB Sticks (CSB04PA10 / CSB04PA11)