This page describes the commands supported by the RapidConnect serial protocol.

Serial Protocol commands are sent between the Host application and MMB Networks Module. The commands are then translated into Zigbee commands by the Module Firmware

If you are new to the RapidConnect Serial Protocol, get started by reviewing the Serial Protocol Overview guide.

Sleep Consultant Packages

Serial Protocol Overview

Serial Protocol overview and architecture guide.

Zigbee Specification References

Provides useful zigbee specification reference data such as Data Types, Status Codes and Zigbee Device ID's.

Primary Headers

(0x55) Utility Frames

This section describes a wide range of command functionality that works on a system-wide level under the Primary Header 0x55.

( PH:0x55 SH:0x00 ) - Reset Command

Overview

(0x01) Network Commissioning Frames

The Network Commissioning command set allows the Host to prompt the Module to either form a network or join an existing network.

Updates to the Zigbee 3.0 Commissioning mechanism have been incorporated into RapidConnect v3.5.0 and above. Network Steering is now the preferred method of joining a new network, while the Network Formation command is used when forming new networks.

(0x02) Security Configuration Frames

This section describes commands that set and report on security keys.

( PH:0x02, SH:0x03 ) - Install Code Request Command

Overview

(0x03) ZigBee Support Configuration Frames

This section describes the commands used to configure RapidConnect IEEE functional device type, as well as the endpoints, clusters and attributes that will logically exist on that device.

( PH:0x03, SH:0x00 ) - Device Type Write Command

Overview

(0x04) ZDO Message Frames

This section describes the two ways, unicast and broadcast, for the Host to send a ZDO command. It also describes the commands sent by the Module to communicate ZDO-level information to the Host.

( PH:0x04, SH:0x01 ) - Send ZDO Unicast Command

Overview

(0x05) ZCL Message Frames

( PH:0x05, SH:0x00 ) - Send ZCL Unicast Command

Overview

The Send ZCL Unicast command is sent by the Host to the Module in order to transmit a custom ZCL message to a target node. The command provides facilities for configuring the Encryption Level of the message, either with Network or Network + APS Encryption, as well as available Response Options, including custom sequence numbers, requiring an APS ACK or enabling processing of a corresponding response with a matching transaction sequence number.

(0x11) General Cluster Frames

The General Clusters command set encompasses the following mandatory ZCL clusters in the general domain:

  • Basic
  • Identify

(0x12) HA Clusters

The HA clusters command set encompasses the following ZCL clusters for common HA applications:

  • On/Off
  • Level Control

(0x0B) Serial Bootload Frames

The commands in this section facilitate serial bootload upgrade of the application operating on the Module. These commands have been implemented per HA 1.2 guidelines.

(PH:0x0B, SH:0x01) - Trigger Bootloader Request Command

Overview

(0x0B) OTA Upgrade Client Frames

The commands in this section facilitate over-the-air (OTA) client of the application operating on the Module. These commands have been implemented per the ZigBee HA 1.2 guidelines.

( PH:0x0B, SH:0x20 ) - OTA Query Configuration Request Command

Overview

(0xB0) OTA Upgrade Server Frames

The commands in this section facilitate over the air (OTA) server of the application operating on the Module. These commands have been implemented per the ZigBee HA 1.2 guidelines.

( PH:0xB0, SH:0x00 ) - OTA Image Notification Command

Overview

(0xD1) Diagnostic Frames

This section describes the commands that initiate and respond to network scans.

( PH:0xD1, SH:0x00 ) - Network Scan Request Command

Overview

(0xDF) Manufacturing Library Frames

Manufacturing Library Start - ( PH:0xDF, SH:0x80 )

Overview

Manufacturing Library Start is sent from the Host to the Module to enable Manufacturing Library functions. The Host must send this frame before using other manufacturing library frames.



Change Log



RapidConnect 3.0.2

Frames Removed:

  • Trust Center Install Code Request
  • Trust Center Install Code Response
  • Bootloader Version Request
  • Bootloader Version Response

Updates to Existing Frames:

  • Module Info Response - Application Info enumerations modified
  • Module Info Response - Hardware Type field renamed to Hardware Version
  • Module Info Response - Hardware Version enumerations modified
  • Module Info Response - Bootloader Type enumerations modified
  • Status Response - Added MMB Unrecognized Command (0x13) to enumerations
  • Trust Center Security Policy Write - Added Incorrect Length (0x07) to Status Response enumerations
  • Trust Center Key Exchange Update - Key Exchange status enumerations expanded
RapidConnect 3.0.1

Frames added for Zigbee 3.0:

  • Trust Center Security Policy Write
  • Trust Center Security Policy Request
  • Trust Center Security Policy Response
  • Trust Center Key Exchange Status Update
  • Trust Center Removed Device Notification
  • Trust Center Install Code Add
  • Trust Center Install Code Request
  • Trust Center Install Code Response
  • Clear Trust Center Install Codes
  • Trust Center Install Code Max Count Request
  • Trust Center Install Code Max Count Response

Updates to existing frames to support BSB03PA1x modules:

  • Module Info Response - Hardware Type enumerations modified to include 0x05 = EFR32MG1B232F256GM32
  • Module Info Response - Bootloader Type enumerations modified to include 0x02 = Gecko Standalone Bootloader